Dr. Fixit Super Latex Waterproofing Solution Technical Data Sheet (TDS) – Kenya

Download the official Technical Data Sheet (TDS) for Dr. Fixit Super Latex Waterproofing Solution. This document contains manufacturer specifications, coverage rate, drying time, and correct application procedures used by professional painters, contractors, and waterproofing specialists in Kenya.

Technical Specifications

Product TypeLiquid Acrylic Latex-Based Waterproofing Solution
FinishMatte / Waterproof Membrane
CoverageApproximately 4–5 m² per litre per coat (depending on surface porosity and method)
Drying TimeTouch dry: 30–60 minutes | Recoat: 2–4 hours | Full cure: 24 hours
ApplicationBrush, Roller, or Spray
Number of Coats2–3 coats for optimal waterproofing

Download Technical Data Sheet (PDF)

Download Dr. Fixit Super Latex Waterproofing Solution TDS PDF

Mixing & Preparation Instructions

Dr. Fixit Super Latex should be thoroughly mixed before application. Ensure no lumps or sediment are present.

Surface must be clean, dry, and free from dust, oil, grease, or loose particles.

Thinning Guidelines

  • Thin the first coat with clean water up to 10% to improve penetration.
  • Second and third coats can be applied neat or with slight thinning (5–10%).

Over-thinning may reduce waterproofing efficiency, while under-thinning the first coat may result in poor adhesion.

Surface Preparation

  • Ensure the substrate is structurally sound, clean, and dry.
  • Fill cracks and joints with appropriate filler or mortar.
  • Remove all loose particles using a wire brush or vacuum.
  • Priming may be done for highly porous surfaces for better adhesion.

Poor surface preparation may lead to seepage, blistering, or reduced lifespan of the waterproofing layer.

Application Method

  • Brush: Apply evenly, avoid pooling
  • Roller: Suitable for large flat surfaces
  • Spray: Recommended for fast coverage on roofs and walls

Recommended coats: 2–3 coats

Apply thin, even coats. Allow each coat to dry before applying the next. Avoid applying under direct sunlight on hot surfaces.

Common Uses

  • Roofs and terraces
  • Balconies and parapets
  • Water tanks (internal & external)
  • Basement walls and foundations
  • Bathrooms, kitchens, and wet areas

More Technical Data Sheets

Browse all paint and waterproofing datasheets: Paint & Waterproofing TDS

Check availability and pricing: View Product Page

Application Guidance & Professional Usage

The TDS provides manufacturer specifications, but correct site application is equally important for durability and waterproofing performance.

For step-by-step instructions, curing tips, and troubleshooting, follow professional guidelines during application.

This guide explains common mistakes and proper application procedures for Kenyan conditions, including roofs, basements, and wet areas.

Frequently Asked Questions

What is Dr. Fixit Super Latex Waterproofing Solution?

Dr. Fixit Super Latex Waterproofing Solution is a liquid acrylic latex-based product that provides effective waterproofing for concrete, masonry, and other building surfaces.

How many coats of Dr. Fixit Super Latex should I apply for proper waterproofing?

Apply 2–3 coats for optimal waterproofing. Allow each coat to dry completely before applying the next.

Can Dr. Fixit Super Latex be used for internal and external water tanks?

Yes, it is suitable for both internal and external water tanks, providing a waterproof barrier.

How should I prepare surfaces before applying Dr. Fixit Super Latex?

Ensure surfaces are clean, dry, free of dust, oil, grease, and loose particles. Fill cracks with appropriate fillers or mortar.

Is it safe to apply Dr. Fixit Super Latex under direct sunlight?

No, avoid applying under direct sunlight. Apply during cooler times of the day to prevent rapid drying and uneven coating.

What is the drying time for Dr. Fixit Super Latex per coat?

Touch dry in 30–60 minutes, recoat after 2–4 hours, and fully cured in 24 hours.

Can I apply Dr. Fixit Super Latex using a spray gun?

Yes, spraying is effective for large areas like roofs and terraces, but ensure uniform coverage to avoid weak spots.

Should the first coat of Dr. Fixit Super Latex be thinned?

Yes, thin the first coat with up to 10% clean water to improve penetration and adhesion.

Can Dr. Fixit Super Latex be applied over existing waterproofing layers?

Yes, but ensure the old layer is clean, stable, and slightly roughened to improve bonding.

Is Dr. Fixit Super Latex suitable for bathrooms and wet areas?

Yes, it can be applied in bathrooms, kitchens, balconies, and other wet areas, provided the substrate is dry and clean.

Which surfaces are compatible with Dr. Fixit Super Latex?

It adheres well to concrete, masonry, brick, plaster, and other porous surfaces.

How should I clean brushes and rollers after using Dr. Fixit Super Latex?

Clean tools immediately with clean water before the solution dries. Hardened material cannot be removed easily.

What is the coverage rate per litre of Dr. Fixit Super Latex?

Approximately 4–5 m² per litre per coat, depending on surface porosity and application method.

Can Dr. Fixit Super Latex be applied in humid or rainy conditions?

Yes, but ensure the surface is dry before application and avoid heavy rainfall until the coating is fully cured.

What safety precautions should I take when using Dr. Fixit Super Latex?

Wear gloves and protective clothing. Avoid contact with eyes and skin, and ensure adequate ventilation during application.

How long will the waterproofing last when applied correctly?

When applied according to manufacturer instructions, it provides long-lasting protection, typically several years, depending on exposure and surface conditions.